Skip to main content
SHIXINDA 时信达
SXD-QG01 Combustible Gas Detector Product Image
Smart Kitchen

SXD-QG01 Combustible Gas Detector

Specification · GB15322.2-2019 · Natural gas (Methane CH₄)

SXD-QG01 is a combustible gas detector designed for on-site detection of natural gas leaks: when the set concentration is reached, it triggers an audible and vi…

Item
Specification
Applicable Standard
GB15322.2-2019
Gas Detected
Natural gas (Methane CH₄)
Detection Principle
Semiconductor type

No. sxd-qg01-combustible-gas-detector · 2026-11-20

Overview

Product Positioning

SXD-QG01 is a combustible gas detector designed for on-site detection of natural gas leaks: when the preset concentration is reached, it triggers a sound-and-light alarm and pushes notifications to the platform, and can be linked to a shut-off valve and exhaust system—moving from "discovering it only after smelling gas" to "taking action as soon as the concentration is reached."

Core Functions

  • Real-time natural gas concentration detection with tiered alarms
  • On-site sound-and-light alarm + remote platform push notifications
  • Supports linkage with emergency shut-off valves and exhaust equipment

Platform Integration

Alarms are sent to the platform via an IoT gateway, and on-duty personnel receive synchronous notifications on their mobile phones; the linkage logic can be configured on the platform side.

Deployment Essentials

Install above gas-using equipment or near pipeline connections (natural gas is lighter than air, so install high), and avoid locations directly exposed to cooking fumes; one unit is recommended per gas-using point.

FAQ

Q: How often should it be calibrated? A: Calibrate periodically according to the product instructions and local regulatory requirements; the platform records device self-checks and offline status.

Q: Can it automatically shut off the gas source? A: It supports linkage with a shut-off valve; an solenoid valve must be configured on site and installed by professional personnel.

Q: What should be done about false alarms? A: Alarm delay and concentration thresholds can be set to reduce false alarms caused by interference such as cooking fumes and alcohol concentration.

Related Recommendations

References

The following are relevant regulations and standards for further verification:

  • Food Safety Law of the People's Republic of China — Official Source
  • Regulations on the Management of School Food Safety and Nutrition and Health (Order No. 45 of the Ministry of Education and two other departments) — Official Source

Applications

智慧校园
智慧校园
智慧工地
智慧工地
园区周界
园区周界
能源站点
能源站点

Core Features

执行标准

GB15322.2-2019

探测气体

天然气(甲烷 CHa)

探测原理

半导体式

报警设定值

8% LEL

Specifications

ItemSpecification
Applicable StandardGB15322.2-2019
Gas DetectedNatural gas (Methane CH₄)
Detection PrincipleSemiconductor type
Alarm Setpoint8% LEL
Alarm MethodLocal audible and visual alarm
Expand all(11)
Alarm & Control FunctionsRelay output: 1 normally open output (max. load 250 VAC/10A); Solenoid valve output: 1 channel 12V pulse output (pulse width 100 ms)
Local Data StorageRecords: 200 alarm events, 200 alarm recovery events, 100 fault events, 100 fault recovery events, 50 power-on events, 50 power-off events, 1 gas sensor failure event
Configuration MethodNFC (mobile app)
Power SupplyDC 12V/1A
Protection RatingIP30

FAQ

How often should calibration be performed?

Calibrate regularly according to the product instructions and local regulatory requirements. The platform records device self-checks and offline status.

Can it automatically cut off the gas source?

It supports linkage with a shut-off valve; an solenoid valve must be configured on site and installed by professional personnel.

What should I do about false alarms?

You can set an alarm delay and concentration threshold to reduce false alarms caused by interference such as oil fumes and alcohol vapor.

Related Products

View All →
SXD-MC305 Rodent Guard Door Sensor Product Image

SXD-MC305 Rodent Barrier Door Sensor

SXD-MC305 is a wireless rat guard door sensor that monitors the open/closed status of the rat guard in real time: if the guard is not placed as required or is removed manually, the platform immediately receives an alert, preventing "rats from getting through and records from being traced."

Learn More →
SXD-GW1000 IoT Gateway Product Image

SXD-GW1000 IoT Gateway

SXD-GW1000 is a LoRaWAN IoT gateway that unifies the connection and platform upload of sensor devices in commercial kitchens—including door magnetic contacts, temperature and humidity sensors, smoke detectors, and combustible gas detectors—solving the problem of "each sensor connecting separately and data scattered across multiple places."

Learn More →
SXD-WS303 Temperature and Humidity Sensor Product Image

SXD-WS303 Temperature and Humidity Sensor

SXD-WS303 is a temperature and humidity sensor designed for online temperature and humidity monitoring in commercial kitchens, warehouses, and cold storage rooms: it automatically triggers alarms when limits are exceeded and can be linked with exhaust and dehumidification equipment, turning "temperature out of limit" from a verbal reminder into a traceable record.

Learn More →
SXD-YG01 Smoke Detector Product Image

SXD-YG01 Smoke Detector

SXD-YG01 is a standalone photoelectric smoke detector designed for early smoke detection in unattended areas such as kitchens, warehouses, and electrical distribution rooms: it provides local audible and visual alarms and uploads data to the platform, while retaining independent alarm capability so it still sounds even when the network is down.

Learn More →

Ready to go smart?

Leave a message or call us for tailored selection advice.

Call Hotline
Call